3referencias

Reverse Osmosis Lines Maspalomas I SWDP

Project data
Situation: San Bartolomé de Tirajana, Spain
Years: 2006 - 2013
Client: Elmasa Tecnología del Agua

Design data
Microfiltration and chemical pretreatment: 1μm
Reverse osmosis frames: 6.000 m3/d (2013) 6.000 m3/d (2010) 1.500 m3/d (2006) 1.250 m3/d (2006)
Flux rate: 12,5-14,5 L/m2/h
High-pressure pumps: Centrifugal and positive displacement
Energy recovery system: Pressure exchange system based on isobaric chambers

 

Reverse Osmosis Lines Maspalomas I SWDP

 

Situation: San Bartolomé de Tirajana, Spain

Client: Elmasa Tecnología del Agua

Capacity: 3.000 - 14.750 m3/d

Galería de imágenes